(under construction)

Description

This resistance measurement node gives a flexible solution to field measurements of common low-value resistive sensors in various configurations. It can measure values of a resistive sensor in quarter-bridge, half-bridge or full-bridge configurations. In addition, the device can measure 'straight' resistors, potmeters, small-signal DC voltages and thermocouples.

img bridge
comp
img
bridge
img
half
img
quarter
img
pt100
img
thermo
img
potmeter
img
dc

Functionality

  • Sample rate 1000Hz down to 1/60Hz
  • Cable compensation using 3-wire measurements
  • Various filtering options
  • Capture min/max/avg at slow message rate
  • Bus ID assigned via serial number
  • Configuration & firmware update via gateway device
  • Possibility for custom firmware with specific signal processing functions
Resistance sensor CAN-bus node

Specifications

  • Full-bridge + cable compensation: 2mV/V for 100%, 1 channel
  • Full-bridge: 2mV/V for 100%, up to 2 channels
  • Half-bridge: 1mV/V for 100%, up to 4 channels
  • Quarter-bridge mode: 1mV/V for 100% with build-in reference
  • Resistance & potentiometer (single-ended): max 3kΩ, up to 6 channels
  • Resistance (differential): max 3kΩ, up to 3 channels
  • Voltage (single-ended): max 3V at unity gain, 25mV at gain=128, up to 6 channels
  • Voltage (differential): max ±3V at unity gain down to ±25mV at 128× gain, up to 3 channels
  • Thermocouple: max 3V at unity gain down to 25mV at 128× gain, up to 3 channels

* multi-channel inputs are always in the same IS group.

Specifications

  • Excitation source 10µA-1.6mA, max 3.3V
  • 24-Bit delta-sigma analog digital converter
  • Cold-junction temperature measurement near connector block
  • Sensor input galvanically isolated from CAN-bus, intrinsic safe 500V isolation made of 1.5mm solid material
  • Operating voltage 9-38VDC, <1W
  • 8-Way 3.5mm screw terminal connection
  • 5-Pin spring-contact termination for CAN, power and shield
  • Ground and shield and 'hazardous-GND' individually terminated to earth via 1nF class Y1 safety capacitors
  • Aluminium IP67 enclosure 64x58mm, height 35mm
  • Integrated mounting flanges (94mm wide), optionally without flanges
  • Two M16 brass cable gland entries in sides
  • Optional with 5-pole & 8-pole industrial M12 plug connections
  • ATEX (IEC 60079) 'ic', 'ec', 'mc' & 'tc'

ATEX

Availability

Item: Description: Status: Price: Action:Preloader
No products yet, please email for your inquiries...